RD (ARD)
2. Speci?cations
1) SPDT/Transfer
Characteristics
Arrangement
Item
SPDT
Speci?cations
Transfer
Contact
Rating
Contact material
Initial contact resistance
Contact input power
Nominal Fail-safe
Gold plating
Max. 100m ? (By voltage drop 6V DC 1A)
120W (at 3GHz)
(V.S.W.R. 1.15 or less, no contact switching,
ambient temperature 40 ° C 104 ° F [SPDT], 25 ° C 77 ° F [Transfer])* 1
840mW (4.5V, 12V DC), 970mW (24V DC) 1,540mW (4.5V, 12V DC), 1,670mW (24V DC)
operating
power
Latching
700mW (4.5V DC), 750mW (12V DC),
900mW (24V DC)
1,200mW (4.5V DC), 1,250mW (12V DC),
1,400mW (24V DC)
Contact rating
Max. 30V 100mA
Indicator rating (with
indicator type only)
Initial contact resistance
Min. switching capacity
(Reference value)
Max. 1 ? (Measured by 5V 100mA)
3V DC, 0.1mA (5 × 10 6 , Reliability level: 10% (3k ? ))
High frequency
to 1 GHz
1 to 4 GHz
4 to 8 GHz* 2
8 to 12.4 GHz
12.4 to 18 GHz
18 to 26.5
GHz* 3
characteristics
(Impedance 50 ? )
V.S.W.R. (max.)
Insertion loss (dB, max.)
Isolation (dB, min.)
1.1
85
0.2
1.15
80
1.25
0.3
70
1.35
0.4
65
1.5
0.5
60
1.7
0.8
55
Insulation resistance (Initial)
Between open
contacts
Min. 1,000 M ? (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
500 Vrms for 1 min. (Detection current: 10mA)
Electrical
characteristics
Breakdown
voltage
(Initial)
Between contact
and coil
Between contact
and earth terminal
Between coil and
earth terminal
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
Time characteristics
(at 20 ° C 68 ° F )
Operate time
Max. 15ms (Nominal operating voltage applied to
the coil, excluding contact bounce time.)
Max. 20ms (Nominal operating voltage applied to
the coil, excluding contact bounce time.)
Shock
Functional
Min. 500 m/s 2 (Half-wave pulse of sine wave: 11ms, detection time: 10 μ s.)
Mechanical
characteristics
resistance
Vibration
resistance
Mechanical
Destructive
Functional
Destructive
Min. 1,000 m/s 2 (Half-wave pulse of sine wave: 11ms.)
10 to 55 Hz at double amplitude of 3mm (Detection time: 10 μ s.)
10 to 55 Hz at double amplitude of 5mm
6GHz type: Min. 10 6
Min. 5 × 10 6
18 and 26.5GHz type: Min. 5 × 10 6
(at 180 cpm)
(All types, at 180 cpm)
Expected life
Electrical
High frequency
contact (Hot switch)
6GHz type: Min. 10 6
18 and 26.5GHz type: Min. 5 × 10 6
(All types, 5W to 3GHz, impedance 50 ? ,
V.S.W.R.; max. 1.2) (at 20 cpm)
Min. 5 × 10 6
(5W to 3GHz, impedance 50 ? , V.S.W.R.; max. 1.2)
(at 20 cpm)
Indicator (with
indicator type only)
5 V DC, 10 mA, Min. 10 6 (at 20 cpm)
Conditions
Conditions for operation,
transport and storage* 4
Ambient temperature: –55 ° C to +85 ° C –67 ° F to +185 ° F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight
Approx. 50g 1.76oz
Approx. 110g 3.88oz
Notes: *1
*2
*3
*4
Factors such as heating of the connected connector in?uence the high frequency characteristics; therefore, please verify under actual conditions of use.
The 6GHz type only has the above characteristics up to 6GHz.
18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer)
The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
ASCTB103E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/